Skip to content
CT500 crash barrier load cell

CT500 three-axis crash barrier load cell ±500 kN

Three-axis crash barrier load cell, 500 kN on the impact axis and 125 kN across it, in a 124 mm stainless steel block that assembles into a barrier face.

±500 kN
Measuring range, Fx
±125 kN
Measuring range, Fy, Fz
< 0.5 % FS
Non-linearity
> 1 800 Hz
Natural frequency
  • Housingstainless steel, IP66
  • Operating temperature−40 to 125 °C
  • Electrical connectionMil-Spec circular connector

CT500 three-axis crash barrier load cell

The CT500 is a three-axis load cell for crash and impact tests against a barrier, with a natural frequency above 1 800 Hz. It mounts to a rigid plate; its 124 × 124 mm face leaves 1 mm between cells, so 64 cells cover the 1 m² face of the Instrumented Crash Barrier System at 125 mm spacing.

It measures up to 500 kN on the impact axis (Fx) and 125 kN on Fy and Fz. The CT440 is the 440 kN three-axis version, and the CT501 the single-axis version, 500 kN.

The cell is made of high-grade stainless steel, sealed to IP66, with all electronics mounted internally and a Mil-Spec circular connector. It works with any data acquisition system; size, load capacity and number of axes can be customized.

In the Instrumented Crash Barrier System, 64 cells come mounted on a 1 m² stainless steel plate at 125 mm spacing, with the signal wires routed inside the plate. The system mounts to the customer’s barrier frame, and several systems extend the barrier face.

CT500, view 2

Specifications

CT500
Measured quantitiesFx · Fy · Fz
Force capacityFx 500 · Fy 125 · Fz 125 kN
Non-linearity≤ 0.5 % FS
Hysteresis≤ 0.5 % FS
Axes3
Natural frequency1 800 Hz (minimum)
Dimensions124 × 124 × 130 mm
MaterialStainless steel
Operating temperature−40 to 125 °C
ProtectionIP66
ConnectionsConnector (Mil-Spec circular)

Resources

Drawings

None for this product.

CAD models

None for this product.

A question on this product?

Describe the measurement. An application engineer answers.

More details to give? Use the full contact form.

Where to send the answer

An application engineer replies within 24 hours on working days.

Contact us

Where to send the answer

An application engineer replies within 24 hours on working days.